100% Pass Your NS0-516 Exam Dumps at First Attempt with TrainingDumps [Q66-Q84]

Share

100% Pass Your NS0-516 Exam Dumps at First Attempt with TrainingDumps

Penetration testers simulate NS0-516 exam PDF


NetApp NS0-516 Exam Topics:

SectionObjectives
Documentation-Describe the process of reviewing and preparing a site for implementation of E-Series.
-Describe the information you give a customer after deploying a solution.
Host Side-Describe the different host connection options for E-Series systems.
-Describe how to configure hosts for multipathing.
Storage Configuration-Describe how to setup alerting and notification for the E-Series system.
-Describe how to create and administer Volume Groups or DDP and associated volumes.
-Describe physical and logical storage requirements.
-Describe the setup of CHAP for an iSCSI environment.
-Describe when to use DDP or Volume Groups.
Hardware-Describe the hardware components in an E-Series storage system.
-Describe Fibre Channel, Ethernet, Infiniband and SAS cabling.
-Describe the appropriate tasks for adding additional storage to an E-Series system.
-Describe drive encryption features.
Toolbox-Describe the tools required to design and implement an E-Series solution.
Troubleshooting-Demonstrate the steps for troubleshooting an E-Series system.
-Demonstrate how to analyze multipathing issues between a host and an E-Series system.
Management-Describe the administrative tasks for managing E-Series systems with SANtricity System Manager.
-Describe the management security features in SANtricity System Manager and SANtricity Unified Manager.
-Describe when and how to configure and use SANtricity Unified Manager.
Protection-Describe how Data Assurance with media scan protects your data.
- Describe SANtricity data protection features.
SAN-Describe the end-to-end network configuration for Fibre Channel and Ethernet.


NetApp NS0-516 Exam Certification Details:

Exam CodeNS0-516 NCIE SAN Specialist E-Series
Number of Questions60
Exam RegistrationPEARSON VUE
Passing Score75%
Duration90 minutes
Recommended TrainingE-Series Fundamentals (WBT)
Configuring and Monitoring NetApp E-Series and EF-Series Storage Systems (ILT)
Sample QuestionsNetApp NS0-516 Sample Questions
Exam Price$150 USD
Exam NameImplementation Engineer SAN Specialist E-Series

 

NEW QUESTION 66
Which interface launches the script engine for a storage system? (Choose the best answer.)

  • A. ALUA
  • B. AMW
  • C. DDP
  • D. EMW
  • E. MPIO

Answer: D

 

NEW QUESTION 67
What is represented by the Headroom graph on the SANtricity System Manager performance tab?

  • A. the remaining performance capability of the physical objects in the storage system
  • B. the percentage of CPU processing capacity that is being used by the operations on the system
  • C. the percentage of I/O associated with the backend disk drives
  • D. the resources that are being consumed by a defined workload

Answer: A

 

NEW QUESTION 68
An orphaned volume occurs during an asynchronous mirror implementation. You must recover the orphaned volume.
In this scenario, which statement is correct?

  • A. Remove the mirroring relationship on the orphan then re-create the mirroring relationship
  • B. Perform a role change on the orphan then re-create the mirroring relationship
  • C. Deactive the mirror consistency group that contains the orphan then re-enable the group
  • D. Suspend mirroring operations on the orphan then resume operations

Answer: A

 

NEW QUESTION 69
What is the SANtricity Client? (Choose the best answer.)

  • A. A GUI or CLI run on a host server used for storage system management
  • B. A host I/O performance modeling interface
  • C. Inter-process communication that supports computer program subordinates
  • D. An OS-dependent collection of utilities for servers attached to SANtricity-managed storage systems
  • E. A host server process that enables storage system management with the storage data path

Answer: D

 

NEW QUESTION 70
How many paths provide optimal redundancy from a host through a switched topology to a storage system?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C

 

NEW QUESTION 71
What would an E-Series system customer use to determine when a specific volume was deleted?

  • A. Recovery Guru
  • B. Storage Array Profile
  • C. Event Log
  • D. Online Help

Answer: C

 

NEW QUESTION 72
You are helping a customer diagnose a performance issue on an E-Series storage system. You decide to measure the amount of data that is being handled over the span of an hour.
In this scenario, what are you measuring?

  • A. I/O alignment
  • B. parity
  • C. IOPS
  • D. throughput

Answer: D

 

NEW QUESTION 73
Exhibit:

Referring to the exhibit, a customer needs to verify the power draw for the uninterruptible power supply (UPS) that is supporting ten E2824 shelves in a cabinet connected to a 100/110 volts power source.
What is the power draw in amps for the UPS?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C

 

NEW QUESTION 74
An administrator is asked to create an asynchronous mirroring environment that supports multiple mirroring relationships, each with different recovery point objectives (RPOs).
In this scenario, how does the administrator create this environment?

  • A. The administrator creates multiple mirror consistency groups with the appropriate RPOs
  • B. The administrator creates a mirror group with the appropriate RPOs
  • C. The administrator creates multiple mirror pairs, each with their own schedule and RPO
  • D. The administrator creates a single consistency group with multiple RPOs

Answer: B

 

NEW QUESTION 75
An E-Series customer can find out when a specific volume was deleted by using the ______. (Choose the best answer.)

  • A. Recovery Guru
  • B. Storage Array Profile
  • C. Major Event Log
  • D. Online Help

Answer: A

 

NEW QUESTION 76
A Snapshot group contains one repository for which associated objects?

  • A. Snapshot volumes
  • B. Consistency groups
  • C. Base volume files
  • D. Snapshot images

Answer: D

 

NEW QUESTION 77
A customer intends to use an E2812 system without expansion shelves. The specification for their Windows host requires that six E-Series data volumes be used.
In this scenario, how should the system be configured?

  • A. three DDPs with the volumes divided equally
  • B. one DDP with all the volumes
  • C. one DDP for each volume
  • D. two DDPs with the volumes divided equally

Answer: B

 

NEW QUESTION 78
According to NetApp recommended practices, is this E2712 storage system cabled for a dual-stack configuration? If not, why?

  • A. No. The cabling has split the top-down-bottom-up configuration.
  • B. No. The cabling to the disk shelves is coming from the host ports.
  • C. Yes. The cabling configuration is correct.
  • D. No. The controllers are only cabled to one "stack."

Answer: C

 

NEW QUESTION 79
What is the 'base' host connectivity provided by the E5500 Controller? (Choose the best answer.)

  • A. iSCSI
  • B. FC
  • C. IB
  • D. iSCSI
  • E. SAS

Answer: B

 

NEW QUESTION 80
Exhibit:

A customer's host is running a Red Hat Enterprise Linux 7.6 server with dm-mp configured for ALUA and is connected to a single volume on the EF280 system that is shown in the exhibit.
In this scenario, how many active/optimized paths are available to the volume?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C

 

NEW QUESTION 81
To discover events that need to be reported to the storage administrator, which log does the Event Monitor poll?

  • A. Recovery Guru log
  • B. Major Event Log
  • C. Array Profile
  • D. ASUP log

Answer: B

 

NEW QUESTION 82
Which two errors would fail a pre-upgrade health check? (choose two.)

  • A. Hot spares are in use
  • B. An excess number of event log events are present
  • C. Volumes are reported on a non-preferred path
  • D. I/O is being processed

Answer: A,B

 

NEW QUESTION 83
The ability of many E-Series controllers to hold an additional firmware image in reserve _________. (Choose the best answer.)

  • A. allows two firmware images to be used at the same time
  • B. allows controller firmware to be downloaded immediately and activated at a later time
  • C. is used for Support use only
  • D. is used to store a backup boot image

Answer: A

 

NEW QUESTION 84
......

All NS0-516 Dumps and Training Courses: https://www.trainingdumps.com/NS0-516_exam-valid-dumps.html

Help candidates to study and pass the NetApp Implementation Engineer SAN Specialist E-Series (NCIE) Exams hassle-free: https://drive.google.com/open?id=1kpZkTpLwcG9F2nRph5J2RjkYNBb8IQ_j